SYNOPSIS

nvme [<global-options>] sanitize-ns <device>
                        [--ish | -I]
                        [--namespace-id=<num> | -n <num>]
                        [--ause | -u]
                        [--sanact=<num> | -a <num>]
                        [--emvs | -e]
                        [--preq | -q]

DESCRIPTION

Submit a sanitize namespace command.

The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).

This page only lists the help texts of the command. A detailed description is still missing.

OPTIONS

-I
--ish

Ignore Shutdown (for NVMe-MI command)

-n <num>
--namespace-id=<num>

identifier of desired namespace

Values: all, -1.

-u
--ause

Allow unrestricted sanitize exit.

-a <num>
--sanact=<num>

Sanitize action: 1 = Exit failure mode,

4 = Start a crypto erase namespace sanitize operation,
5 = Exit media verification state

Values: exit-failure, start-crypto-erase, exit-media-verification.

-e
--emvs

Enter media verification state.

-q
--preq

Require the sanitize operation to purge user data, as defined by IEEE Std 2883, or fail.

GLOBAL OPTIONS

The following options are defined at the top-level nvme command and are available to this subcommand:

--dry-run

Print the command that would be executed, but do not actually execute it.

--no-ioctl-probing

Disable probing for 64-bit IOCTL support.

--no-retries

Disable retry logic on transient errors.

-o <fmt>
--output-format=<fmt>

Set the reporting format to normal, tabular, 'json, or binary. Only one output format may be used at a time.

--output-format-version=<version>

Select the output format version. Version 1 uses the original field naming, while version 2 (default) provides more consistent and script-friendly field names. Other versions are rejected.

--quiet

Suppress informational messages. Errors are still reported, and --quiet cancels any --verbose for the library log level.

--set-options=<key=value>[,<key=value>…]

Set libnvme library options for this invocation. Supported keys are force-4k, mi-probe-enabled, test-base-dir and test-sysfs-dir.

--timeout=<ms>

Set the timeout for the command in milliseconds. infinite or -1 waits without a time limit (0xffffffff).

-v
--verbose

Increase the level of detail in the output. May be specified multiple times to further increase verbosity.

These options can also be set as machine-wide defaults in nvme-cli.conf(5). A command-line flag always overrides the file.

EXAMPLES

No examples provided yet.

NVME